Skip to content
Zambrano EnterprisesZambrano
Fuel System Upgrades and Replacements for fuel storage and dispensing systems
Upgrades and replacements

Replace the tank once, with the scope defined before anyone digs.

Aging tanks, failed sumps, containment gaps and capacity limits, resolved with a design and permit path that tells the contractor exactly what to build.

Send us the situation.

Photos, a notice, an inspection report, or a few sentences. Most inquiries receive a response within one business day.

Photos, notices, reports

Files are used only to evaluate your project inquiry and are handled in accordance with our Privacy Policy.

Or call (845) 642-7754

15+ years in fuel systemsOwner-led, one point of contactNationwide, deep New York experience
You might be here because

The call usually starts like this.

If one of these sounds like your site, the form above is the fastest way to get a defined path back.

  • Our tank is old and needs to be replaced.

  • We need more fuel-storage capacity.

  • We need to replace our underground tank with an aboveground tank.

  • Our UST sump failed testing.

  • The inspector says our overfill protection and secondary containment do not meet the current rule.

  • Our fleet-fueling island is 25 years old and every component is from a different generation.

What you receive

Concrete deliverables, not a proposal to write one.

  • Existing-conditions assessment: tank and registration records, test history, site constraints
  • Replacement or upgrade strategy with options (repair, replace, convert UST to AST, phase the work)
  • Permit drawing set for the replacement or modification
  • Equipment schedule and construction scope narrative for comparable contractor bids
  • AHJ application package, including closure or modification filings for the tank coming out
  • Closeout: test certificates, registration updates and deregistration of removed tanks
Why ZE

How ZE approaches fuel system upgrades and replacements.

Zambrano Enterprises provides specialized fuel-system design and technical consulting services. When professional engineering review or certification is required, ZE coordinates with appropriately licensed Professional Engineers through established professional relationships nationwide.

  • Replace or repair, decided on evidence

    Test reports, tank construction and age, the condition of the sumps and piping, and what the AHJ will accept determine the recommendation. ZE does not default to full replacement, and does not recommend a repair the county will reject.

  • The old tank comes out cleanly

    Closure notification, removal or in-place closure, sampling requirements and PBS or DEQ deregistration are designed into the same project as the new tank, so the file is closed rather than left open for the next inspection or property transaction.

  • Comparable bids

    A defined replacement scope means every contractor is pricing substantially the same system. That is the difference between three proposals you can compare and three proposals describing three different jobs.

The process

How the work runs.

The full process
  1. STEP 1

    Investigate

    Records, registrations, test history, a site walk and a conversation about what is failing, what is running out of room and what the facility needs to keep doing during the work.

  2. STEP 2

    Develop a compliance and design strategy

    Options with tradeoffs: repair versus replace, like-for-like versus UST-to-AST, capacity, location, phasing and which AHJ approvals each option needs. You choose a path with the facts in front of you.

  3. STEP 3

    Design

    The drawing set, equipment schedule and scope narrative for the chosen option, with the closure of the outgoing tank and the corrections to overfill, spill and containment included.

  4. STEP 4

    Permit

    Permit to construct and closure filings with the county, state and local officials, plus comment responses.

  5. STEP 5

    Support construction and closeout

    Bid review, submittal and RFI review, test and inspection coordination, then registration updates, deregistration of the old tank and the permit to operate.

Common questions

About fuel system upgrades and replacements.

Not answered here? Ask directly.

Talk to a Fuel-System Specialist
What drives the cost of a fuel tank replacement?

ZE does not quote prices, because the range is wide and the reasons are specific to the site. The big drivers: whether the tank is underground or aboveground (excavation, removal, disposal and backfill are a large share of a UST job); tank size, listing and construction; how much of the piping, sumps and dispensers come out with it; what is found in the ground (contaminated soil changes the job); electrical, paving, canopy and site work disturbed by the excavation; permit fees, PE sealing, testing and inspection; how long the facility can be down, and whether the work has to be phased to keep it open. A design-first scope lets you see these before contractors price them, and lets the contractors price the same job.

When does a tank actually have to be replaced?

There is no universal age limit. Replacement is usually forced by a failed tightness or sump test, corrosion or structural findings, a single-wall tank or piping in a jurisdiction that requires secondary containment on replacement, an AHJ order or a violation that cannot be corrected in place, or an operational need for more capacity. Suffolk County keeps existing USTs on a testing schedule under Article 12, and a tank that keeps failing is a replacement candidate even without an order. ZE gives you the evidence and the recommendation.

Can we convert an underground tank to an aboveground tank?

Often, and it is common for #2 fuel oil and generator diesel. The AST has to be sited to fire code separation distances (a UL 2085 protected tank frequently makes a tight site work), the fill, vent, overfill and containment have to meet the county's AST requirements, and the UST has to be properly closed and deregistered. In Suffolk County both the new AST and the closure go through SCDHS. The design covers both halves.

Our UST sump failed. Do we replace the sump or the whole system?

Usually the sump, sometimes the fittings, occasionally more. A sound sump with a failed penetration boot can often be corrected with new entry fittings. A cracked sump, a sump with no test boundary, or one the AHJ will not accept for repair gets replaced. If the piping or the tank also shows problems in the same test round, the conversation changes. ZE reads the test report and the sump before recommending either.

Will replacing one tank force us to bring the whole facility up to current code?

Not automatically, but modifications trigger current requirements for the parts you touch, and some AHJs treat a substantial modification as a new installation for review purposes. In Suffolk County, altering an existing facility requires a permit to construct, and the reviewed drawings will be held to current Article 12 standards for the work shown. ZE identifies what the scope triggers before you commit to it, so there are no surprise upgrades at inspection.

Send us the situation. We'll tell you the path.

Photos, a violation notice, an inspection report, or just a description of the site. Matt reviews every inquiry personally and comes back with a clear next step.

CallDiscuss Your Project